A different way to bring fluid to a surface — and take it away again.
The Multiplexer combines a dense array of impinging jets with adjacent return channels. Supply and extraction are designed together, at the same spatial scale. VELA, NIVO and further model variants develop this principle for different applications and design requirements.
01 / Supply and return, integrated in one surface.
HEAT & MASS EXCHANGE
Cooling / Heating / Drying / Spraying
01 / THE PRINCIPLE
Give every supply region a nearby way back.
Jet impingement directs fluid towards a target surface. The Multiplexer integrates a finely distributed extraction network alongside the supply network, so fluid can leave close to where it arrives.
The illustrations show possible flow arrangements, not simulation results or manufacturing drawings. Blue identifies supply, red identifies return, and gray represents separating material. The colours do not indicate temperature.
CONVENTIONAL ARRANGEMENT
Centralized extraction
Strong crossflow can deflect the outer jets towards the outlets, greatly reducing their direct impingement on the target surface. Dashed arrows indicate weakened impingement in this conceptual illustration.
MULTIPLEXER ARRANGEMENT
Distributed local extraction
Adjacent return channels remove conditioned fluid locally. The aim is to limit crossflow interference and continually renew fluid at the interface.
02 / Supply and return, side by side at the working face.
01
Distribute
Separate supply and return connections lead into parallel, alternating channels.
02
Rearrange
Internal channel transitions turn a slot pattern into an interleaved checkerboard of supply and extraction openings.
03
Impingement & return
Jets meet the target surface. Adjacent channels collect the conditioned fluid and guide it into the return network.
At equal total volumetric flow, a larger combined return area allows a lower average return velocity than the nozzle jet velocity. The flow arrows are schematic and not to scale.
03 / APPLICATION AREAS
Surface processes. A shared flow challenge.
The architecture is intended for processes that require closely distributed heat or mass exchange with a surface.
↘
Cooling
Bring cooling fluid towards the surface and extract the warmed return flow nearby.
↗
Heating
Deliver heated fluid locally, with extraction distributed across the same working area.
≈
Drying
Supply drying air and remove moisture-laden fluid close to the exchange interface.
⋮
Spraying
Explore distributed delivery and local collection for surface-treatment processes.
04 / PARAMETRIC BY DESIGN
Adapt the architecture to the process.
The active area, channel density and operating conditions are part of one design problem.
Supply and return geometries are developed together. Complex internal transitions are designed with additive manufacturing in mind, subject to the selected material and printing process.
Surface & grid
Active area, jet pitch and channel count
Flow conditions
Flow rate and target jet velocity
System balance
Channel density, pressure loss and fan-energy demand
Manufacturing
Internal geometry, material and process constraints
05 / MULTIPLEXER MODELS
A family of models. A shared flow principle.
VELA is one implementation of the Multiplexer architecture. NIVO and further application-specific models explore other component arrangements. The model defines the overall architecture; the internal channel evolution is a separate design choice within its interface constraints.
REFERENCE MODEL
VELA
A component-based architecture illustrated below in 3D, from separated supply and return passages through internal transitions to the working face.
An alternative Multiplexer concept with its own component arrangement. It shares the principle of separated supply and return networks and an interleaved working face.
Geometry, interfaces and manufacturing requirements are assessed for the selected configuration.
APPLICATION-SPECIFIC DEVELOPMENT
Further models
Other model variants can be developed around the available space, target surface, fluid and required operating conditions.
The straight and planar channel transitions shown in VELA are one geometric approach. Internal passages can also be developed with stepped, rounded, diagonal or smoothly varying transitions, depending on the model, application and desired performance.
03 / Alternative geometric routes from alternating slots to a checkerboard.
Angular & stepped
Straight-edged, serrated transitions redistribute the slot pattern through angular intermediate sections.
Rounded transitions
Rounded intermediate contours provide another way to shape the transition towards separate cells.
Smooth & undulating
Gradually varying boundaries explore curved paths between the inlet pattern and the working-face grid.
Diagonal & faceted
Inclined partitions and faceted intermediate sections offer further ways to rearrange the channels.
Choose the geometry around the requirements
Target flow uniformity, allowable pressure loss, jet velocity, available depth, cleanability and manufacturing constraints guide the choice.
The complete three-dimensional channel design must keep the two flow networks separated and provide suitable flow areas. Performance is assessed through flow analysis and, where needed, measurements.
07 / EXPLORE VELA
A perspective on the hardware.
Explore the presentation model of all seven VELA components, including the internal channels and smoothly curved nozzles. Internal channels are shown by default, with the casing and nozzles hidden. Use the controls below to show them.
VELA / INTERNAL ARCHITECTURE3D
Loading 3D view…
TEZZIT / ADVANCED HEAT & MASS EXCHANGE
Let’s explore your surface process.
Discuss the application, flow requirements and a suitable validation approach.